P5) 416 OFPPk (Standard Configuration)


416 STANDARD CONFIGURATION
With a single (1S) 416 pack, you can add more to configure to 3S, 4S, 7S & 14S. Or any number of pack you required just by "Series" the pack together. Treat a whole pack like a battery with + & - terminal. Linking between pack can be done easily with Nickel Connect plate. Cabling is a option.

Pack Calculator
Assuming using:
18650, 3.7-4.1V, 2200mAh, Weight 45g (Battery Not Included)

(3S 64P) Configuration
(1S) + (1S) + (1S) = 3S 64P
Voltage Range: ~11.1V-12.3V
Watt Hours: 1500Wh - 1700Wh
Battery Needed : 192 pcs
Complete Weight: (~3kg x 3 ) 9kg
3 x Unit Dimension: (L400 x W98 x H83 mm)

(4S 64P) Configuration
(1S) + (1S) + (1S)  + (1S) = 4S 64P
Voltage Range: ~14.8V-16.4V
Watt Hours: 2000Wh - 2300Wh
Battery Needed : 256 pcs
Complete Weight: (~3kg x 4 ) 12kg
4 x Unit Dimension: (L400 x W98 x H83 mm)

(7S 64P) Configuration
(1S) + (1S) + (1S)  + (1S)+ (1S) + (1S)  + (1S) = 7S 64P
Voltage Range: ~25.9V-28.7V
Watt Hours: 3600Wh - 4000Wh
Battery Needed : 448 pcs
Complete Weight: (~3kg x 7 ) 21kg
7 x Unit Dimension: (L400 x W98 x H83 mm)

(14S 64P) Configuration
(1S) + (1S) + (1S)  + (1S)+ (1S) + (1S)  + (1S)+
(1S) + (1S) + (1S)  + (1S)+ (1S) + (1S)  + (1S) = 14S 64P
Voltage Range: ~51.8V-57.4V
Watt Hours: 7200Wh - 8000Wh
Battery Needed : 896 pcs
Complete Weight: (~3kg x 14 ) 42kg
14 x Unit Dimension: (L400 x W98 x H83 mm)

Capacity is greatly depends on each battery rating. Using higher rating with similar configuration will result in higher overall capacity and vice versa.

BMS (Battery Monitoring System) is a critical part of this system. It monitors and control the balancing of voltages across all the packs in the system. Balancing is needed for Lithium batteries to protect from operating outside its safe operating range. Selecting a good BMS with rated capacity is a MUST on a big system like Powerwall.

Battery repack /sorting Utility (Courtesy of secondlifestorage.com)
https://secondlifestorage.com/repackr.php

Here's the list of Appliances Energy Use Chart for your reference:
Appliance Energy Use Chart

Link to: